Fatemeh GholamiMahyari, modified 6 Years ago.
Illegal option for reaeration formula
Youngling Posts: 23 Join Date: 4/8/16 Recent Posts
Hello Everyone
I am working on a wastewater pond modelling for almost a year. I am really enjoying working with D-waq. Besides my results seems very well. I should thank you for your excellent software and support team. However recently I have a difficult with CO2 reaetation . since I activated this process my model does not run and the error bellow appears in the window.
runid: 18nov
Parallel processing with 1 processor(s)
SIMULATION STARTED
INTEGRATION ROUTINE = 15
Illegal option for reaeration formula
Stopped with error code : 1
I attached lsp and inp file. If anyone can help me I would appreciate it.
Thanks
Fatemeh
I am working on a wastewater pond modelling for almost a year. I am really enjoying working with D-waq. Besides my results seems very well. I should thank you for your excellent software and support team. However recently I have a difficult with CO2 reaetation . since I activated this process my model does not run and the error bellow appears in the window.
runid: 18nov
Parallel processing with 1 processor(s)
SIMULATION STARTED
INTEGRATION ROUTINE = 15
Illegal option for reaeration formula
Stopped with error code : 1
I attached lsp and inp file. If anyone can help me I would appreciate it.
Thanks
Fatemeh
Attachments:
Arjen Markus, modified 6 Years ago.
RE: Illegal option for reaeration formula
Jedi Knight Posts: 219 Join Date: 1/26/11 Recent Posts
Hello Fatemeh,
the documentation states that for CO2 only the options 0, 1, 4, 11 and 13 are available. Would one of these suit your purpose?
Regards,
Arjen
the documentation states that for CO2 only the options 0, 1, 4, 11 and 13 are available. Would one of these suit your purpose?
Regards,
Arjen
Fatemeh GholamiMahyari, modified 6 Years ago.
RE: Illegal option for reaeration formula
Youngling Posts: 23 Join Date: 4/8/16 Recent Posts
Dear Arjen
Thanks for quick respond and, I know what is the problem now. I did not pay attention to SWRearCO2 options. I think one of them can be the one I want.
Regards,
Fatemeh
Thanks for quick respond and, I know what is the problem now. I did not pay attention to SWRearCO2 options. I think one of them can be the one I want.
Regards,
Fatemeh
Fatemeh GholamiMahyari, modified 6 Years ago.
RE: Illegal option for reaeration formula
Youngling Posts: 23 Join Date: 4/8/16 Recent Posts
Dear Arjen
I changed SWRearCO2 to 0, 1, 4, 11 and 13 but I have the same problem. Did I miss something else?
Regards,
Fateme
I changed SWRearCO2 to 0, 1, 4, 11 and 13 but I have the same problem. Did I miss something else?
Regards,
Fateme
Arjen Markus, modified 6 Years ago.
RE: Illegal option for reaeration formula
Jedi Knight Posts: 219 Join Date: 1/26/11 Recent Posts
Are you sure that you changed the right parameter? I checked the code and also ran a small test - this message only appears if the option is outside the range 0 to 13. The options 11 and 13 are specific to CO2 but the others can be used - with some caution perhaps, as they are based on the physics, not the chemistry - for CO2 as well.