Hi,

I'm trying to activate the "Sedimentation adsorbed Cr (Sed_Cr)" process, however, the following message is displayed: 

PARTMP: Kinetic sorption for Chromium not implemented!
 Stopped with error code :           1

Can someone help me?
Thanks.

AM
Arjen Markus, modified 3 Months ago.

RE: Sedimentation adsorbed Cr (Sed_Cr)

Jedi Knight Posts: 222 Join Date: 1/26/11 Recent Posts

The error message is quite clear: slow or kinetic sorption is not implemented for this metal. You will have to rely instead on equilibrium sorption. That is in general the recommended way. In this case use the total concentration and not the separate adsorbed and dissolved concentrations. These are available as output.

FC
Franciane Curbani, modified 3 Months ago.

RE: Sedimentation adsorbed Cr (Sed_Cr)

Youngling Posts: 2 Join Date: 7/15/14 Recent Posts

Thanks, Arjen. I did what you suggested and it worked.