null

Message Boards

i don't understand that the maening of the 'discharge' in waq modelling.

U
Anonymous, modified 3 Years ago.

i don't understand that the maening of the 'discharge' in waq modelling.

Posts: 1
Dear.

when i try to test the waq modelling using the waq tutorial, the set of waq tutorial is 'friesian_tidal_inlet', there are difference 'discharge rate' between the flow input and waq input.
the value of discharge in flow input is '3 cms' and the value of discharge of waq is '10 cms'. So, is there special reason for the difference between the flow and waq?
and, could you tell us references data for related waq tutorial model set such as papers or reports el al.

regards.
deok woo
Michel Jeuken, modified 3 Years ago.

RE: i don't understand that the maening of the 'discharge' in waq modelling (Answer)

Jedi Knight Posts: 156 Join Date: 1/21/13 Recent Posts
Hi,

I don't think there a a particular reason for the difference in values. It is is just a show case without any real background. I guess that the Delwaq example is based on an older version of the FLOW example, and the FLOW example was changed later on. There are no publications about this simple example.

Michel